Locations
Locations refer to physical points in space which are used for storing cryptographic material or performing actions using the cryptographic material and adhere to a set of criteria which focus on achieving a high level of security - specifically with respect to:
-
Protecting access to devices which store cryptographic material
-
Mitigating the risk stemming from natural disaster and other black swan events such as civil unrest or war.
-
Reducing the risk of exposing cryptographic material, for example via side-channel attacks
There are three sub-types of Locations, one which is used for performing any actions related to the management of the cryptographic material life-cycle and is referred to as the Management Location, one for long term secure storage of cryptographic material such as Smart Cards which are used to decrypt Shards, referred to as a Storage Location, and a location for Ceremonies, known as the Ceremony Location.
Level 1
This level of defenses is largely focused on remote attacks, and as such does not have strict requirements about the location.
Examples
-
Personal domicile
-
Co-working space
-
Regular office (non specific to QVS)
Reference Design
-
SHOULD have ability to control physical access to room
-
SHOULD be a space that's randomly selected to minimize the likelihood of an adversary deploying equipment into the location before it's used
Level 2
This level of defenses is focused on insider threats and as such requires a considerably higher standard as it needs to mitigate threats which stem from individuals who have privileged access.
Examples
-
Purpose specific facility for QVS
-
Short term rental
-
Hotel room
-
Moving vehicle
Reference Design
-
MUST have physical access restrictions which require identification
-
MUST have the ability to require more than 1 person to gain access
- This control can be both physical, for example in vaults which require 2 keys for access AND/OR process level, where the personnel of the facility may verify the identity of one or more individuals
-
SHOULD have anti-fire systems
-
SHOULD have anti-flood systems
-
SHOULD be in facilities controlled by organizations which are ideally immune to being legally subpoenaed
Level 3
-
MUST have anti-fire systems
-
MUST have anti-flood systems
-
MUST have 24/7 security monitoring
-
MUST be in different geographic locations
- This ensures that natural disasters are not likely to impact multiple locations simultaneously
-
SHOULD be facilities owned by different organizations to reduce the risk of collusion unless the organization who owns the QVS system has their own facility such as a SCIF.
Level 4 (SCIF)
-
MUST not have cameras installed inside of the room
-
MUST not have windows with direct line of sight to monitors
-
MUST have all walls protected with EM shielding which adheres to the TEMPEST standard NATO SDIP-27 Level A
-
SHOULD have seismic detectors